CASE STUDY
Thompson Community Centre
Richmond, BC
Thompson Community Centre in Richmond spans two structures — a 10,590 sq ft annex and a 6,566 sq ft main building — each on a different roofing timeline. The City of Richmond retained Pinpoint to scan both buildings and give a clear, section-by-section picture of where the roof was performing and where it wasn’t, ahead of maintenance and capital planning.
Pinpoint’s team scanned every roof section across both buildings, combining daytime capacitance moisture scanning with a nighttime infrared drone pass — respecting manufacturer warranty limits on the newer main building sections by relying on non-invasive methods rather than core cuts.
17,156
Sq Ft Roof Surveyed
Annex: Dry
R1, R2, R3 Confirmed Dry
7–10%
Suspected Wet, Main Building
D
Main Building Grade
Jul
2025 Survey Completed
// Survey Scope & Methodology
Two buildings, two roofing eras, one consistent process
Pinpoint scanned all sections of both buildings using an RWS roof scanner and Tramex Dec Scanner, cross-checked with a DJI Mavic 3 Enterprise nighttime thermal drone pass. A calibration core cut in a known-dry area on the annex established the moisture baseline before the full survey began.
On the annex’s older roof (R1–R3), a single core cut confirmed dry conditions with minimal disruption to the membrane. On the main building’s newer roof (RA2), core testing was intentionally withheld to protect the manufacturer’s warranty — findings there rely on non-invasive scanning alone, pending City approval for further verification.
All four roof sections (RA-1 through RA-4) scanned across the facility
// What We Found
A healthy annex, a main building asking for closer attention
The annex roof (R1, R2, R3) scanned completely dry across the board — no active moisture intrusion, performing as intended. The main building told a more mixed story: RA1, RA4, RA5, and RA6 showed elevated moisture readings, though standing water from HVAC discharge on RA5/RA6 prevented reliable scanning and needs to be resolved before those sections can be fully assessed. RA3 held the highest concentration of blisters on the property, but every one tested dry at time of inspection. RA2, the newest roof system, showed a few isolated high readings that couldn’t be core-verified without risking the warranty. RA7 scanned dry.
Annex R1–R3
10,590 sq ft · Confirmed dry
Main RA1, RA4–RA67–10%
Elevated readings, HVAC runoff limits data
Main RA3
Most blisters on site, all tested dry
Main RA2 & RA7
Newer roof, isolated readings; RA7 dry
Recommendation
The annex requires no action beyond routine monitoring. For the main building, Pinpoint recommended: securing City approval for selective core verification in RA2 and other high-reading sections; rechecking RA3’s blisters seasonally; resolving HVAC discharge drainage so standing water no longer masks scan accuracy; targeted repair of fishmouths, ridges, and localized membrane failures; and continued annual inspection across both buildings to track progression.
Project Participants
Client :
City of Richmond / Garland Canada
Location:
5151 Granville Ave, Richmond, BC
Roof System:
Modified bitumen (SBS), TPO section on annex patch area
Survey Method:
RWS scanner, Tramex Dec Scanner + MEX5, DJI Mavic 3 Enterprise thermal drone
Delivered by:
Pinpoint Diagnostics Group

Thompson Community Centre
Case Study PDF